With long outlet spigot

Reference | d1 | d2 | SDR range | B | D | h | L | L1 | t | t1 | z | Weight [kg] | BX | PU |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
616417 | 32 | 20 | 11 | 62 | 46 | 22 | 116 | 117 | 44 | 42 | 14 | 0,110 | 30 | 540 |
616418 | 40 | 32 | 11 | 70 | 55 | 25 | 146 | 148 | 46 | 51 | 28 | 0,170 | 20 | 360 |
616419 | 50 | 32 | 11 - 17,6 | 82 | 69 | 28 | 175 | 158 | 55 | 51 | 33 | 0,300 | 15 | 270 |
616420 | 50 | 40 | 11 - 17,6 | 82 | 69 | 28 | 175 | 167 | 55 | 55 | 33 | 0,320 | 15 | 270 |
616421 | 63 | 32 | 11 - 17,6 | 96 | 84 | 32 | 197 | 173 | 63 | 51 | 36 | 0,440 | 10 | 180 |
616422 | 63 | 40 | 11 - 17,6 | 96 | 84 | 32 | 197 | 182 | 63 | 55 | 36 | 0,450 | 10 | 180 |
616423 | 63 | 50 | 11 - 17,6 | 96 | 84 | 32 | 197 | 197 | 63 | 60 | 36 | 0,500 | 10 | 180 |
FRIALEN safety fittings can be fused with SDR11 - SDR17.6 pipes.
Minimum wall thickness s minimum ≥ 3 mm.
Other levels of SDR can be processed on request.
Please note the mandatory labels directly on the product.
DVGW test mark issued: DV-8601AU2248, DV-8606AU2249 and DV-8611AU2250.
Dimension B = Diameter D with contact pin
Areas of Application
The FRIALEN reduced TA red pieces are used for pipe outlets of HD-PE pipelines.
Assembly Instructions
The fusion of the pipe ends with the FRIALEN TA red takes place by FRIALEN-fusing – leakproof and longitudinally strong.
The pipe ends are prepared (removing the oxide layer/cleaning) according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”).
Good reasons for using the FRIALEN TA red:
- Large coupler depth for ease of pipe guiding (no holding clamps required)
- At dim. up to d1 63, Length of outlet spigot dimensioned for two fusion operations
- Extra wide fusion zones
- Maximum stability through great wall thickness
- Cold zones at the front side and in the middle of the coupler
- Exposed heating coil for direct heat transmission to the pipe
- Small annular gap for build-up of optimum joining pressure in the fusion zone
- Touch proof electric contacts
- Durable batch marking
- Individually wrapped for dirt protection