UB NXT SDR 11

Coupler with easily removable inner stop, SDR 11

Coupler UB NXT SDR 11 with inner stop

  • Gas, water and H2
  • Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
  • Material: PE 100 RC
  • Easily removable inner stop
  • Safety technology
  • Large insertion depth for good pipe routing (no holding devices required)
  • DVGW test mark: DV-8601AU2248, DV-8606AU2249, DV-8611AU2250 and DW-8610CN04200

Note:

The availability of the articles must be requested individually for specific markets or countries, as these countries will be switched one by one in 2025/2026.

Go back Data sheet

PE 100 SDR 11

Maximum permissible working pressure 16 bar (water) / 10 bar (gas)

Reference d SDR range B D h L t z Weight kg PU
617235 20 11 46,5 28 16,5 76 37 2 0,030 3520
617236 25 11 51,5 33 18,2 81 39,5 2 0,037 2880.0
617237 32 11 - 17 58,6 40 18,2 82 40 2 0,044 1920.0
617238 40 11 - 17 67,4 49,5 18,5 83 40,5 2 0,060 1280.0
617239 50 11 - 17 78,2 61,5 21,4 88 43 2 0,088 800
617240 63 11 - 17 92,4 77 23,5 95 46,5 2 0,137 480
617241 75 11 - 17 105,4 91 25,6 105 51,5 2 0,203 400
617242 90 11 - 17 122,2 109 29,5 115,5 56,8 2 0,327 240
617243 110 11 - 17 144 132,5 33,9 120 59 2 0,480 192
617244 125 11 - 17 160,4 150 35,6 145 71,5 2 0,724 128
617245 140 11 - 17 177 168 38,5 160 79 2 0,993 96
617246 160 11 - 17 198,8 192 42,6 176 87 2 1,416 64

Areas of Application

The FRIALEN-Coupler UB NXT SDR11 is used for cut and lay pipe connections.

Additional areas of application:

  • Pipe connectors (gas, water and 100% H2)
  • Replacement of pipe sections
  • Subsequent connection to a pipe system
  • Sealing option for minor pipe damage

Assembly Instructions

The pipe ends are joined to the FRIALEN coupler UB NXT SDR11 by electrofusion welding – tight and longitudinally force-fit.

The pipe ends are prepared according to the general installation instructions (see “Assembly Instructions” for “FRIALEN-Safety Fittings”)

This involves removing the oxide layer of the pipe end and cleaning of pipe surface. Please note that spigot of valves must be at least half as long as the coupler. The center strip is embossed to make it easy to mark the peeling area.

For removal of the oxide layer, FWSG scraper tools are available which facilitate a uniform swarf removal and a reproducible quality of the fusion area preparation.

Good reasons for using the FRIALEN-Slide-over Coupler UB NXT SDR11:

  • Large coupler depth for ease of pipe guiding (no holding clamps required)
  • Maximized fusion zones
  • Safety Fittting Design
  • 25% lower CO2-Footprint
  • Cold zones at the front side and in the middle of the coupler
  • Exposed heating coil for direct heat transmission in the fusion zone
  • Lowest energy consumption and variable voltage
  • Optimised tolerances for “perfect fit” for easy installation
  • Touch proof electric contacts
  • Fusion indicators for visual fusion control
  • Angle and insertion depth markings for quick and safe installation
  • Durable batch marking
  • Individually wrapped for dirt protection
  • 2D barcode for tracing back the fitting (Traceability-Coding).